Insulated Self-Contained Kettle, Gas-Fired, Low Rim Models: LGB-1F, 20F, -25F -30F, -40F, -60F, -80F -100F

Email us about this product

Gas-Fired, 2/3 Jacketed Insulated for Safety™ Deep Drawn Construction, Stationary, Floor Mounted, Low Rim, Available in 20 (76L), 25 (95L), 30 (114L), 40 (151L), 60 (227L), 80 (303L) and 100 (379L) Gallon Capacity

Kettle System

  • Seamless deep-drawn 304 kettle liner with an integrally formed radius lip
  • 304 stainless steel draw-off tube and welds
  • 2" compression draw-off

Kettle Protection System:

  • Thermostat temperature control, 150˚F - 260˚F
  • Pressure relief valve
  • Air eliminator valve
  • Pressure gauge
  • Jacket-water fill and sight glass
  • Automatic low water cut off and indicator light
  • Field replaceable heating elements
Constructed of 304L stainless steel: 
  • Fully insulated kettle jacket and outer casing 
  • Electronic ignition, 120V standard
  • Outer casing seam welded to radius lip
  • Seam welded control console 
  • Stainless, one-piece, domed cover, actuator assisted on 40-125 gallons
  • Perforated disc strainer, 1/4" holes 
  • Adjustable bullet feet

Optional Features and Accessories (link) are available for faucets, security, safety and cleaning/maintenance 

Model Dimensions (link) refer to specification sheet (dims) 

Electrical: 120V standard, 208/240V optional, 50/60 Hz, single phase, 1 Amp

Model
Gallons / Liters Lbs / Kgs BTU Rating Natural / Propane Piping/Pressure Natural  Piping/Pressure Propane
LGB-15F 15 / 56.8 350/ 159 63,200 / 59,600 1/2" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 1/2" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-20F
20 / 75.7 395 / 179 66,700 / 67,800 1/2" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 1/2" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-25F 25 / 94.6 440 / 200 79,700 / 83,100 1/2" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 1/2" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-30F
30 / 113.6 480 / 218 79,700 / 83,100 3/4" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 3/4" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c
LGB-40F 40 / 151.4 555 / 252 106,800 / 108,500 3/4" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 3/4" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-60F 60 / 227.1 720/ 327 131,400 / 131,100 3/4" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 3/4" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-80F 80 / 302.8 805 / 365 154,800 / 149,200 3/4" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 3/4" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.
LGB-100F 100 / 378.5 860 / 390 154,800 / 149,200 3/4" IPS, Inlet range 5.0 -7.0" w.c., Outlet range 3.5" w.c. 3/4" IPS, Inlet range 12.0 -14.0" w.c., Outlet range 10.0" w.c.

 

 Approval agencies may include ASME, NSF, UL, ETL, CSA and CGA